ANALISA PERHITUNGAN BEBAN PENDINGINAN RUANG PERANGKAT INTERNET DI PT. X - SITE KEDATON

Authors

  • SUKO WINARNO

DOI:

https://doi.org/10.22441/jtm.v8i3.4581

Keywords:

Cooling load, Air Conditioning, beban pendinginan, system HVAC

Abstract

Abstract -- The cooling process in the internet device room has an important function in maintaining room temperature so that the equipments in the room stay at the desired temperature. With optimal cooling, the equipments in the room are expected to function optimally. The author analyzes the condition of the internet device room with the research method used is by taking field data and analyzing the calculation of the data using formula formulas obtained from the literature. After calculating the data , then the average value of the Thermal load of the room is 3260 Watt,  the average of room temperature is 22.95 0 C, the average enthalpy value in the room is 42.72 kJ / kg.a. Then the enthalpy value of the evaporator is 35.86 kJ / kg.a. Then the average value of the mass flow rate coming out of the evaporator is 0.48 Kg / s. From these calculations it can be concluded that the highest room temperature is at 11.00 AM, the average room thermal load value is at 1.20 PM, then the highest enthalpy value of the room occurs at 11.00 AM, then the highest value of enthalpy of the evaporator occurs at 11.00 AM, and the highest average value of mass flow rate occurs at 1.20 PM.

Downloads

Download data is not yet available.

References

G. P. Anugrah, A. Ismardi, M. Sc, T. A. Ajiwiguna, and M. Eng, “Rancang Bangun Pendingin Untuk Perangkat Elektronik Pada Green House,” e-Proceeding Eng., vol. 4, no. 3, pp. 3928–3935, 2017.

V. Nomor, P. Pemasangan, E. Fan, D. I. Ruang, F. Teknik, and U. Terhadap, “Keywords : Abstract :,” vol. 15, no. September, pp. 70–76, 2016.

D. Suntoro, R. D. S, and K. Ahadi, “PERHITUNGAN BEBAN PENDINGINAN PADA RUANGAN DI PERKANTORAN PT . INDONESIA POWER UPJP PESANGGARAN BALI COOLING CAPACITY CALCULATION FOR OFFICE BUILDING,” vol. 17, no. 1, pp. 19–30, 2018.

U. Sulawesi, I. Persero, S. A. Safitri, and R. Hantoro, “Desain dan Analisis Sistem Pengkondisian Udara Berbasis Computational Fluid Dynamics ( CFD ),” vol. 7, no. 1, pp. 95–100, 2018.

H. Abdurrachman, M. Sibarani, and J. V. Tuapetel, “Perancangan Air Conditioning ( AC ) Sentral pada Gedung G Institut Teknologi Indonesia,” vol. 2, no. 2, pp. 35–41, 2018.

Khoeri, A. Solichan, and S. Raharjo, “Efisiensi MusiCool-22 Dengan Proses Retrofit Pada AC Merek Daikin 3 PK Di Unit Rektorat Unimus,” Media Elektr., vol. 10, no. 1, pp. 39–45, 2017.

S. Harahap, A. Hamid, and I. Hidayat, “Perhitungan Ulang Beban Pendinginan Pada Ruang Auditorium Gedung Manggala Wanabakti Blok III Kementerian Kehutanan Jakarta,” Progr. Stud. Tek. Mesin, Fak. Tek. Univ. Mercu Buana, Jakarta, pp. 149–154, 2014.

A. Kurniawati and G. Doloksaribu, “Tower Universitas Mercu Buana Lantai 5 Dan,” pp. 246–254, 2009.

G. Penumpang and K. Api, “C~26,7,” vol. II, no. November, pp. 37–44, 2016.

P. V. Beban, W. P. Dan, T. Ruang, T. Performasi, and M. Pendingin, “Mastur , Khanif Setiyawan , Bambang Sugiantoro,” vol. 17, no. 1, pp. 43–47, 2016.

A. Aziz, U. Riau, and R. I. Mainil, “Penggunaan Thermal Energy Storage sebagai Penyejuk Udara Ruangan dan Pemanas Air pada Residential Air Conditioning Hibrida,” no. April 2016, 2015.

W. H. Piarah and F. Hamzah, “Penentuan Efisiensi Dan Koefisien Prestasi Mesin Pendingin Merk Panasonic Cu-Pc05Nkj ½ Pk,” vol. 7, pp. 978–979, 2013.

Published

2020-04-27

How to Cite

[1]
S. WINARNO, “ANALISA PERHITUNGAN BEBAN PENDINGINAN RUANG PERANGKAT INTERNET DI PT. X - SITE KEDATON”, JTM, vol. 8, no. 3, pp. 120–141, Apr. 2020.

Issue

Section

Articles

Similar Articles

> >> 

You may also start an advanced similarity search for this article.