Many aspects affect the performance of a power plant . One of her in the form of fluctuations in load of Control Center Interkoneksi expenses electricity network , as that occurred at the power plant Unit 1 South Minahasa. It is the possibility of big will air an influence on the efficiency of boiler power plant , which is now a reference in the assessment Performance Regulatory Base a steam power plant. Through the analysis of the effect of fluctuations in the workload of the Efficiency Boiler power plant Amurang Unit 1 Unit 1, the expected performance of the existing power plant can be in the know , s ehingga Performance Regulatory Base him untracked . Thus the energy saving effort will be achieved and at the same time encourage environmental preservation efforts. Because the Amurang PLTU Unit 1 uses medium rank coal / LRC which is environmentally friendly (low sulfur and ash content).

Downloads

Download data is not yet available.

Author Biography

Dadang Suhendra Permana, Mercubuana University

department teknik

References

Abdul Qodir A ,. (2015). Electricity Heat Rate. Retrieved from aabdulqodir wordpress website: https://aabdulqodir.wordpress.com / 2015/01/10 / heat-rate-power-plant

Adhi N. , Agus . (2014). Analysis of the Effect of Coal Quality on Generation Costs (Case Study at Rembang Power Plant) . Electrical Media, Vol. 7 No. 1 . Sultan Agung Islamic University.

Aziz, Amiral, & Andi RH (201 5 ). Evaluate the Heat Rate and Efficiency of a Power Plant Using Coal Different from the Design Specifications . Jakarta: Mechanical Engineering, Trisakti University Jakarta.

University, PLN. (2014). Operation of PLTU 1 Edition 2014 . Udallat Suralaya. Cilegon.

Manual Book, Amurang PLTU Unit I, 2 X 30 MW Power Plant Boiler Operation

Mavendra, Dede and Prasetyadi, A, (2016). Power Efficiency Calculations for PLTGU engines With operating patterns 2-2-1 and 3-3-1 PT. Indonesia Power Generation Unit Semarang . Faculty of Science and Technology, Sanata Dharma University: Yogyakarta

Effendy, Mohamad (2018). Analysis of the Effect of the Tanjung Awar-Awar 350 MW Steam Power Plant Load Capacity on the Efficiency of the Turbine Generator QFSN-350-2 UNIT 1 . Mechanical Engineering Department, Engineering Faculty, Surabaya State University